Page Config ▼
⚠ A preview of the page. The gauge beside the phone shows it as the panel draws it.
When Web Config is open, Auto Page Rotate is paused (if on) and the display visible will match what is open on the Web Config.
Repaints the five colours above with the palette this template was designed around. Nothing is stored until Save Page, and every colour stays editable afterwards.
Settings ▼
Default Page
Page shown after boot
Needle Sweep on Boot
Sweep the needles or bars through their full range and back when the gauge starts. Only on needle, cluster and bar pages, and only when one is the page the gauge boots to
Auto Range from Warning Value
Size each dial to its warning value instead of the full default scale, e.g. a 20 psi boost warning gives a dial that ends at 25 psi. A dial with a low warning moves its start too, except where the scale starts at zero. Dials without a warning, RPM and speed keep their usual range
Auto Cycle Time
How often the gauge rotates pages when Auto Rotate is on in its menu. Disabled turns it off and hides the Auto Rotate button from the gauge menu.
WiFi Auto On
Configure if WiFi should turn on automatically. Recommended to turn off when you have finished configuring
Odometer
Track total distance travelled, integrated from vehicle speed (works on every ECU protocol). Turn on to set a starting value; turn off to clear it and reset
Normal Brightness
Saved to device immediately
Dimmed Brightness
20%
Dimmer Control
What switches the gauge to its dimmed brightness. CAN follows your Haltech ECU's lighting — ideal when your lights are controlled by an ECU or PD16 style device.
Off uses the gauge's own Brightness card.
Synchronise with other gauges
Dim several gauges together. Set one gauge as the Host: its Brightness card dims them all. Set the others as Clients: they follow the Host and hide their own Brightness card.
⚠ Gauge synchronisation is a beta feature
Units
Show Units on Gauge Face
Append units to temp & pressure names in smaller text
Alerts / Warnings ▼
Check Engine Light
Show a CEL on this gauge if CEL triggered
Pit Limiter Alert
Flash a fullscreen green overlay when the pit limiter is active
Oil Pressure Alert
Flash a fullscreen red overlay when oil pressure leaves the set band
Alternator Not Charging
Flash a fullscreen orange overlay when battery voltage stays below the set value for 5 seconds with the engine running
Temperature Alert (1)
Flash a fullscreen amber overlay when the selected temperature leaves the set band
Temperature Alert (2)
Flash a fullscreen amber overlay when the selected temperature leaves the set band
Temperature Alert (3)
Flash a fullscreen amber overlay when the selected temperature leaves the set band
Generic Alert (1)
Flash a fullscreen amber overlay with the metric name when it goes outside the range you set
Generic Alert (2)
Flash a fullscreen amber overlay with the metric name when it goes outside the range you set
Generic Alert (3)
Flash a fullscreen amber overlay with the metric name when it goes outside the range you set
Generic Alert (4)
Flash a fullscreen amber overlay with the metric name when it goes outside the range you set
Wideband Alert (1)
Watch an air/fuel sensor and flash a fullscreen amber RICH or LEAN warning — either against fixed limits, or against your target lambda or another wideband
Wideband Alert (2)
Watch an air/fuel sensor and flash a fullscreen amber RICH or LEAN warning — either against fixed limits, or against your target lambda or another wideband
Shift Light Takeover
Enabling this turns the gauge into a shiftlight — when the shift points are met the gauge fills the screen with the preset colour, overriding what is on display currently. At the final shift point it strobes rapidly
Keypad Action (1)
Switch a CAN keypad button on when the metric goes above the max or below the min you set, and off again when it comes back inside
Keypad Action (2)
Switch a CAN keypad button on when the metric goes above the max or below the min you set, and off again when it comes back inside
Keypad Action (3)
Switch a CAN keypad button on when the metric goes above the max or below the min you set, and off again when it comes back inside
Page Rule (1)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
Page Rule (2)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
Page Rule (3)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
Page Rule (4)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
Page Rule (5)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
Page Rule (6)
Switch to the chosen page while the metric is above or below the values you set. Auto rotate pauses, and the gauge returns to the page it was on once the metric has been back inside for 2 seconds
CAN Keypad ▼
Enable CAN Keypad
Swipe up from gauge to open
Configure / Live Mode
Live turns this panel into a working keypad
Keypad LED Feedback
Light button LEDs based on keypad state
⚠ CAN Keypad LED Feedback is a beta feature
Button 1
Momentary
Button 2
Momentary
Button 3
Momentary
Button 4
Momentary
Button 5
Momentary
Button 6
Momentary
Button 7
Momentary
Button 8
Momentary
Button 9
Momentary
Button 10
Momentary
Button 11
Momentary
Button 12
Momentary
Button 13
Momentary
Button 14
Momentary
Button 15
Momentary
Changes are saved to the device automatically. Buttons 9–15 appear for the 3x5 keypads and take up to 11 characters.
Keypad Theme
Colours used by the keypad screen on the gauge.
Drawn over the background colour at its native size. Upload images under Personalisation → Image Manager.
Transparent buttons
Idle buttons show only their border and text, so the background shows through. Active buttons still fill with the glow colour.
Highlight on a button while it is active. The button fill is a dimmed shade of this colour.
Main button labels.
Screen header (KEYPAD A / B) and the small BTN 1…8 captions.
LED Left
LED Middle
LED Right
Personalisation ▼
Image Manager
Show custom Images on your gauge, select a PNG or JPG and adjust the resolution, crop and colour profile to optimise the image for the gauge.
Uploads are switched off in the demo.
Boot Screen Duration
How long the startup screen stays up before the first gauge page. This is the total, so a gauge that spends longer starting its radio and bus simply shows less of it afterwards rather than adding to it. Your own boot image, if you have one, has its own duration above.
Advanced Functions ▼
Demo Data Mode
Pauses CAN data and replaces data with sine-wave signals for demonstration and display purposes
Turn Indicator Arrows
Show turn-indicator arrows on pages that ask for them. Reads the standard light-state bits, so it stays dark on a bus that never sends them.
Combined Indicator
Light both arrows from either indicator, the way a single-lamp cluster behaves, instead of each arrow following its own side.
High Beam Light
Show the blue high-beam dot on pages that ask for it.
ECU / Protocol
Changing protocol resets page metrics and alerts to that protocol's defaults and reboots. Your layouts, colours, names and other settings are kept.
Screen Rotation
Rotates display and touch — for incorrect mounting or polarisation checks
Boot Delay
For fine tuning turn on times when used with multiple gauges, or to allow fade/gradient with turn on times
Wireless Access Point
Network details can’t be changed in the demo.
Customise Network Details
Rename the gauge's own hotspot or set a password — leave off to keep the defaults
Internet Connection
Network details can’t be changed in the demo.
Internet Connection
Connect the gauge to your Wi-Fi so it can check for firmware updates
Backup
Backups are switched off in the demo.
Restore
Restoring is switched off in the demo.
Uploads are switched off in the demo.
Restores pages, display and alert settings, brightness, keypad setup and theming, and (when the backup is from the same ECU/protocol) custom CAN metrics and CSM6 calibrations.
Not included: WiFi name and password, and the internet connection name and password (they stay with the gauge that owns them), uploaded splash and background images (only which one is selected is stored), the odometer reading, and the ECU/protocol itself — switch that separately first if the backup is from a different one.
⚠ Warning: An altered .json file may cause corruption or damage to your gauge and may require USB recovery.
Restart and Restore Defaults are switched off in the demo.
Firmware Update
Firmware updates need a gauge connected.
⚠ Do not power off your gauge during a firmware update — it may take 1–2 minutes to complete. Back up your settings first, as a firmware update may clear them.
Uploads are switched off in the demo.
Support ▼
For wiring diagrams, setup guides and troubleshooting, go to KrispyGauge.com/support/Krispygauge
Wiring
Red
Switched ignition 12V+ from ECU
Black
Ground
Yellow
CAN High
Green
CAN Low
⚠ Take care when wiring your gauge not to create a short, and never short CAN High or CAN Low to 12V or ground — doing so may damage your gauge or disrupt the CAN bus network.
The gauge has a built-in, software-enabled 120Ω CAN termination resistor, configurable in settings.
CanBus Test
Lists every metric for your selected ECU protocol with its current value, so you can see which ones your vehicle supports. On OBD2 the gauge asks for each metric in turn, so give it about 30 seconds before treating one as unsupported.
CAN Bus Analyser
Reboots the gauge into a listen-only CAN readout. The gauge does not display normally in this mode. Any power cycle returns it to normal. Bus bitrate is selected in the analyser itself.
The CAN analyser runs on the gauge itself.