Fixed datastream decoded from Syvecs S6 and S7 at 1 Mbit/s, using 11-bit standard IDs from 0x600.
Support for this ECU is unverified. The frame list below has not been confirmed against a physical Syvecs unit. Check a known value on screen against your tuning software before relying on any channel.
Set the CAN bus speed to 1 Mbit/s in the gauge's ECU Type menu. Syvecs publishes its frame definitions only behind a forum login, so the frame list here comes from the OpenECU Alliance listing and the decoding is inferred rather than confirmed against a device.
| CAN ID | Signal(s) | Unit |
|---|---|---|
| 0x600 Engine Data 1 (10 ms) |
RPM
Accel Ped
TPS
|
rpm
%
%
|
| 0x601 Temperature Data (100 ms) |
Cool Tmp
IAT
Oil Tmp
Fuel Tmp
|
°C
°C
°C
°C
|
| 0x602 Fuel and Lambda (20 ms) |
WB B1
AFR
|
—
—
|
| 0x603 Ignition and Injection (20 ms) |
Ign Angle | ° |
| 0x604 Boost Control (20 ms) |
MAP
Boost
Boost Tgt
|
kPa
psi
psi
|
| 0x605 Pressure Data (50 ms) |
Oil Pres
Fuel Pres
Cool Prs
Baro
|
psi
psi
psi
kPa
|
| 0x606 Vehicle and Wheel Speeds (20 ms) |
Speed
Speed FL
Speed FR
Speed RL
|
km/h
km/h
km/h
km/h
|
| 0x608 EGT Sensors 1-4 (100 ms) |
EGT 1
EGT 2
EGT 3
EGT 4
|
°C
°C
°C
°C
|
| 0x609 EGT Sensors 5-8 (100 ms) |
EGT 5
EGT 6
EGT 7
EGT 8
|
°C
°C
°C
°C
|
| 0x60A Knock Control (20 ms) |
Knock 1
Knock 2
|
%
%
|
| 0x60B Lambda Bank 2 (50 ms) |
WB B2 | — |
| 0x60C Cam Angles (50 ms) |
Int Cam 1
Exh Cam 1
Int Cam 2
Exh Cam 2
|
°
°
°
°
|
| 0x612 G-Force Data (20 ms) |
Lat G
Long G
Vert G
|
g
g
g
|