Docs / Syvecs / Supported Signals
Syvecs

Supported Signals

Fixed datastream decoded from Syvecs S6 and S7 at 1 Mbit/s, using 11-bit standard IDs from 0x600.

1 Mbit/s 11-bit Standard IDs

Support for this ECU is unverified. The frame list below has not been confirmed against a physical Syvecs unit. Check a known value on screen against your tuning software before relying on any channel.

Set the CAN bus speed to 1 Mbit/s in the gauge's ECU Type menu. Syvecs publishes its frame definitions only behind a forum login, so the frame list here comes from the OpenECU Alliance listing and the decoding is inferred rather than confirmed against a device.

Datastream Frames
CAN IDSignal(s)Unit
0x600
Engine Data 1 (10 ms)
RPM Accel Ped TPS
rpm % %
0x601
Temperature Data (100 ms)
Cool Tmp IAT Oil Tmp Fuel Tmp
°C °C °C °C
0x602
Fuel and Lambda (20 ms)
WB B1 AFR
— —
0x603
Ignition and Injection (20 ms)
Ign Angle °
0x604
Boost Control (20 ms)
MAP Boost Boost Tgt
kPa psi psi
0x605
Pressure Data (50 ms)
Oil Pres Fuel Pres Cool Prs Baro
psi psi psi kPa
0x606
Vehicle and Wheel Speeds (20 ms)
Speed Speed FL Speed FR Speed RL
km/h km/h km/h km/h
0x608
EGT Sensors 1-4 (100 ms)
EGT 1 EGT 2 EGT 3 EGT 4
°C °C °C °C
0x609
EGT Sensors 5-8 (100 ms)
EGT 5 EGT 6 EGT 7 EGT 8
°C °C °C °C
0x60A
Knock Control (20 ms)
Knock 1 Knock 2
% %
0x60B
Lambda Bank 2 (50 ms)
WB B2 —
0x60C
Cam Angles (50 ms)
Int Cam 1 Exh Cam 1 Int Cam 2 Exh Cam 2
° ° ° °
0x612
G-Force Data (20 ms)
Lat G Long G Vert G
g g g